The VAE-660 Six-phase protective relay tester is designed to test all the major protection testing projects, including the 27 underfrequency protection, 59 overcurrent protection, 67 undervoltage protection, 81 overfrequency protection, 87 differential protection, 51 time overcurrent protection, 50 boundary protection, 21 distance protection, 86 rate of change of frequency protection, and 32 directional power protection, and others. This tester is capable of accurately measuring and analyzing the performance of the tested power systems, ensuring that the relays operate within their specified parameters, and helping ensure the continuous and stable operation of the power grid.
Relay Test SystemUniversal Relay Test Set and Commissioning Tool |
Powerful six-phase relay testing and moreThe VAE-660 is economical 6-phase protection relay tester, which outputs 6-phase current(6×30A) & 6-phase voltage(6×120V) for testing conventional protection relays. The embedded industrial PC with 8” LCD screen, keyboard and trackball mouse are adopted to make VAE-660 run without a PC. Download Relay Test System Brochure |
Key featuresThe VAE-660 is all-in-one relay tester, which outputs 6-phase current(6×30A) & 6-phase voltage(6×120V) for testing conventional protection relays. The embedded industrial PC with 8” LCD screen, keyboard and trackball mouse are adopted to make VAE-660 run without a PC. It is also available to connect VAE-660 to PC for completing various tests.\ The new high-fidelity linear amplifier is used for VAE-660 to avoid high and medium frequency interference on the test site, and ensure smooth and accurate waveform from large current to small current.
|
Compatible AppsUniversal AC TestThis application is mainly used to test the action value, return value, sensitivity angle, and action time of various AC relays such as voltage relays, current relays, and power direction relays. This application is also the most basic application of the entire testing system, which can provide 6 voltage and 6 current outputs simultaneously. In addition, under the manual control test mode, the amplitude, angle, and frequency of each voltage and current can be adjusted arbitrarily. Distance & Zero Sequence Protection APPIn 110KV and above line protection, normally distance and zero sequence protection is set as main protection of line, and they often concentrate in a set of protective tester. The testing module of distance and zero sequence protection is a software developed aiming at this situation, which can complete automatically all kinds of earthing distance, phase to phase distance and zero sequence protection. Differential Protection Test AppThe unit of differential protection is designed according to the characteristics of micro-computer type or integrates circuit type transformer, generator and differential protection of Motor. It is used for testing automatically its characteristics of ratio control, harmonic control, action time, etc. Different from the ‘characteristic test of differential relay control’, this module does not do the test by directly loading action current and brake current on test, but loading primary current and secondary current on differential protective tester by simulating them,then it will combin action current and brake current by the protection. |
Current Generator
Setting range |
6-phase AC(L-N) |
6x0…30A |
3-phase AC(L-N) |
3x0…60A |
|
1-phase AC(LL-LN) |
1x0…180A |
|
DC(L-N) |
6x0…±10 A |
|
Power |
6-phase AC(L-N) |
6x300VA at 30A |
3-phase AC(L-N) |
3x450VA at 60A |
|
1-phase AC(LL-LN) |
1x1000VA at 180A |
|
DC(L-N) |
6x70VA at 10A |
|
Accuracy |
AC: ≤0.2% |
|
DC: ≤0.5% |
||
Resolution |
1mA |
Voltage Generator
Setting range |
6-phase AC(L-N) |
6x0…120V |
3-phase AC(L-N) |
3x0…240V |
|
DC(L-N) |
6x0…±160V |
|
Power |
6-phase AC(L-N) |
6x80VA at 120V |
3-phase AC(L-N) |
3x100VA at 240V |
|
DC(L-N) |
6x70VA at 160V |
|
Accuracy |
AC: ≤0.2% |
|
DC: ≤0.5% |
||
Resolution |
1mV |
Auxiliary DC Supply
Voltage range |
110V/220V(max.1.5A) |
Power |
max.165VA/330VA |
Digital Inputs
Number |
8 |
Input characteristics |
idle contact or potential-free contact |
Threshold characteristics |
“0”:0~6V; “1”:12V~250V |
Max. measuring time |
999999.999s |
Time accuracy |
±1ms |
Time resolution |
1ms |
Digital Outputs
Number |
8 |
Type |
idle contact |
Break capacity |
250VAC/0.5A, 250VDC/0.2A |
General Generators
Frequency |
range: 0~1000Hz |
accuracy:<1mHz(0~65Hz);<10mHz(65~450Hz);<20mHz(450~1000Hz) |
|
resolution: 0.01Hz |
|
Phase |
range: -360° ~+360° |
accuracy: 0.1° |
|
resolution: 0.1° |
|
Harmonic |
superposition order: 2~20 times |
distortion: ≤0.5% |
Power Supply
Nominal input voltage |
customized (AC230V/120V±10%, 1-phase) |
Nominal frequency |
50/60 Hz |
Rated current |
10A at 230V / 12A at 120V |
Connection |
standard AC socket (IEC 60320) |
Environmental Conditions
Operation temperature |
0 ... +50 °C (+32 ... +122 °F) |
Storage temperature |
-25 ... +70 °C (-13 ... +158 °F) |
Humidity range |
relative humidity 5 ... 95 %, non-condensing |
Vibration |
IEC 60068-2-6(20m/s2 at 10 ... 150 Hz) |
Miscellaneous
Weight |
20.3kg(44.75 lb) |
Dimensions (W x H x D, without handle) |
470×550×280mm(18.50x21.65x11.02 in) |
Connection port |
2 USB ports, 1 serial port |
The VAE-660 is the economical 6-phase Protection Relay Tester for users all over the world.
Copyright © 2020 VA TECHNOLOGY CO.,LTD All rights Reserved.