VACTP200P

CT/PT Analyzer

All-in-one instrument-transformer analyzer for protection CTs, measuring CTs, TP-class CTs and inductive PTs — knee-point up to 40 kV.

CT ratio 1–30000 · ±0.05%
PT ratio 1–10000 · ±0.05%
Knee-point voltage up to 40
Output voltage / current 0–180 V / 0–12 A
Phase accuracy ±2
Weight 9

Overview

Technical Specifications

Specification Value Unit
Test standards IEC 61869-2 (IEC 60044-1, 60044-6) · IEC 61869-3 (IEC 60044-2) · IEEE/ANSI C57.13
Max. knee-point voltage 40 kV
Measurement principle Low-frequency excitation / voltage method
Platform DSP + ARM, embedded Linux
Display 5.7″ LCD
Operation Multi-function rotary mouse · local or PC remote
Output voltage 0 – 180 V RMS
Output current 0 – 12 (RMS) · 36 (peak) A
Voltage measurement accuracy ±0.05 %
CT ratio range / accuracy 1 – 30000 / ±0.05 %
PT ratio range / accuracy 1 – 10000 / ±0.05 %
Phase accuracy / resolution ±2 min / 0.01 min
Secondary winding resistance 0 – 300 Ω · accuracy 0.1 % ±1 mΩ
Burden 0 – 300 VA · accuracy 0.1 % ±0.1 VA
Memory > 3000 test-result groups
Nominal input voltage AC 230 V / 120 V ±10 % (customized), 1-phase
Nominal frequency 50 / 60 Hz
Rated current 10 A at 230 V · 12 A at 120 V
Connection Standard AC socket (IEC 60320)
Operating temperature 0 … +50 °C
Storage temperature −25 … +70 °C
Humidity 5 … 95 % RH, non-condensing
Vibration IEC 60068-2-6 (20 m/s² at 10–150 Hz)
Weight 9 kg
Dimensions (W×H×D, without handle) 340 × 300 × 150 mm
Connection ports 2 × USB 2.0 · 1 communication port

Key Features

Complete CT/PT coverage

Protection CTs, measuring CTs, TP-class CTs and inductive PTs per IEC 61869-2/-3 and IEEE/ANSI C57.13.

40 kV knee-point capability on-site

Low-frequency excitation derives high-equivalence knee-point voltages (up to 40 kV) without a large external HV source.

0.05 % ratio accuracy

Voltage-method ratio, polarity, ratio-error and phase-displacement measurement with ±0.05 % accuracy.

One-click automatic test

Complete test routine finishes in seconds with a single click of the patented multi-function rotary mouse.

Secondary winding resistance & burden

Measures 0–300 Ω winding resistance and 0–300 VA burden with 0.1 % accuracy.

Local & PC remote operation

Embedded Linux platform with 5.7″ LCD for stand-alone use, plus remote PC control.

Built-in thermal printer

Print test reports directly in the field; store >3000 result groups on board.

Light and portable

Only 9 kg (19.84 lb) in a 340×300×150 mm case.

Applications

Substation CT/PT testing

Acceptance, routine and diagnostic testing of current and voltage transformers on-site.

Protection & measuring CTs

Excitation, ratio, polarity, error curve, resistance and burden tests for all CT classes.

TP-class CT testing

Transient-protection CT characterization for modern distance and differential protection.

Manufacturer QA

Production-line and factory acceptance testing in instrument-transformer plants.

Calibration laboratories

Reference-standard testing and certification of CT/PT units.

Frequently Asked Questions

Which instrument transformers can the VACTP200P test?

Protection CTs, measuring CTs, TP-class CTs and inductive PTs (voltage transformers), covering ratio, polarity, excitation characteristic, error curve, secondary resistance and burden — per IEC 61869-2/-3 and IEEE/ANSI C57.13.

Does it need a separate high-voltage source to test 40 kV knee-point CTs?

No. The analyzer uses a low-frequency excitation principle, so very high equivalent excitation voltages (up to 40 kV knee point) are derived from a low-power 0–180 V / 0–12 A output without a large external high-voltage supply. This makes on-site high-knee-point testing practical and safe.

Can it print reports in the field?

Yes — a built-in thermal printer prints test results directly, and more than 3000 result groups can be stored internally for later transfer by USB.