VAE-660

Six-Phase Protection Relay Test System

Six current + six voltage channels with 1000 VA single-phase power for differential, distance and high-burden relay testing.

Current output 6×0–30 A AC
Single-phase current 1×0–180 A
Voltage output 6×0–120 V AC / 3×0–240 V
Accuracy AC ≤0.2% · DC ≤0.5%
Phase range ±360°
Weight 20.3

Overview

Technical Specifications

Specification Value Unit
Six-phase AC (L-N) setting range 6 × 0 – 30 A
Three-phase AC (parallel) setting range 3 × 0 – 60 A
Single-phase AC (parallel) setting range 1 × 0 – 180 A
DC setting range 6 × 0 – ±10 A
Power – 6-phase AC 6 × 300 VA at 30 A
Power – 3-phase AC 3 × 450 VA at 60 A
Power – 1-phase AC 1 × 1000 VA at 180 A
Power – DC 6 × 70 VA at 10 A
Accuracy AC ≤ 0.2 % · DC ≤ 0.5 %
Resolution 1 mA
Six-phase AC (L-N) setting range 6 × 0 – 120 V
Three-phase AC (L-L) setting range 3 × 0 – 240 V
DC setting range 6 × 0 – ±160 V
Power – 6-phase AC 6 × 80 VA at 120 V
Power – 3-phase AC 3 × 100 VA at 240 V
Power – DC 6 × 70 VA at 160 V
Accuracy AC ≤ 0.2 % · DC ≤ 0.5 %
Resolution 1 mV
Voltage range 110 / 220 V
Max. current 1.5 A
Power max. 165 / 330 VA
Number 8
Input characteristics Idle contact or potential-free contact
Threshold characteristics “0”: 0–6 V · “1”: 12–250 V
Max. measuring time 999999.999 s
Time accuracy ±1 ms
Time resolution 1 ms
Number 8
Type Idle contact
Break capacity 250 V AC / 0.5 A · 250 V DC / 0.2 A
Frequency range 0 – 1000 Hz
Frequency accuracy < 1 mHz (0–65 Hz) · < 10 mHz (65–450 Hz) · < 20 mHz (450–1000 Hz)
Frequency resolution 0.01 Hz
Phase range / accuracy / resolution −360° … +360° · 0.1° · 0.1°
Harmonic superposition 2 – 20
Harmonic distortion ≤ 0.5 %
Nominal input voltage AC 230 V / 120 V ±10 % (customized), 1-phase
Nominal frequency 50 / 60 Hz
Rated current 10 A at 230 V · 12 A at 120 V
Connection Standard AC socket (IEC 60320)
Operating temperature 0 … +50 °C
Storage temperature −25 … +70 °C
Humidity 5 … 95 % RH, non-condensing
Vibration IEC 60068-2-6 (20 m/s² at 10–150 Hz)
Weight 20.3 kg
Dimensions (W×H×D, without handle) 470 × 550 × 280 mm
Connection ports 2 USB · 1 serial

Key Features

Six independent current channels

6×0–30 A with 300 VA per phase — enough for three-phase differential testing with all currents and voltages synchronized.

High-current parallel output

3×0–60 A or 1×0–180 A at 1000 VA for high-burden and high-current relay applications.

Six voltage channels

6×0–120 V AC (L-N) and 3×0–240 V (L-L) connection for complete three-phase voltage output.

AC & DC in one unit

6×0–±10 A DC current and 6×0–±160 V DC voltage extend coverage to DC trip and monitoring circuits.

High accuracy & resolution

AC ≤0.2% / DC ≤0.5% accuracy with 1 mA and 1 mV resolution.

Wide ±360° phase control

0.1° accuracy and resolution for precise phase-angle testing.

Precision frequency source

0–1000 Hz with <1 mHz accuracy below 65 Hz for frequency relays and synchronization tests.

Embedded PC + 8/8 binary I/O

Stand-alone test execution on the integrated PC, with 8 binary inputs and 8 binary outputs for full scheme logic.

Applications

Transformer & generator differential

Six-phase synchronized injection for multi-winding differential protection testing.

Busbar & line differential

Multi-ended differential and high-impedance busbar schemes.

Distance & auto-reclosing

Distance protection, power swing and auto-reclosing scheme tests.

High-burden relay testing

High-power output for electromechanical relays with heavy burdens.

Training & labs

Advanced protection test laboratories and relay training centers.

Frequently Asked Questions

When is a six-phase relay test set necessary?

Six-phase current outputs are required for transformer/generator/busbar differential testing where three-phase current injection into two sets of windings (or two ends) must be synchronized, and for applications needing simultaneous three-phase current and three-phase voltage. For most single-ended overcurrent/distance schemes a three-phase set (VAE-430) is sufficient.

Can the VAE-660 output 180 A on a single phase?

Yes. The three-phase channels can be paralleled to deliver 3 × 0–60 A, and all channels paralleled to deliver 1 × 0–180 A at up to 1000 VA for high-current applications.

Does it operate without a PC?

Yes. The VAE-660 integrates an embedded industrial PC with an LCD, so tests can be executed stand-alone. USB and serial interfaces are available for PC-based automation and results transfer.